LECROY WAVEPRO 7100AXXL CALIBRATION and LECROY WAVEPRO 7100AXXL REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the LECROY WAVEPRO 7100AXXL Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   LECROY WAVEPRO 7100AXXL   Description / Specification:    
LECROY WAVEPRO 7100AXXL 4 Ch 1 GHz WavePro Digital Oscilloscope

The LeCroy WavePro 7100AXXL delivers fast, accurate measurements associated more often with high-end lab oscilloscopes. Common Jitter and Timing measurements for clock and timing analysis enhance its capabilities.Wrap this performance in a very attractive price, and the LeCroy WavePro oscilloscope is the ideal solution for your test needs. The LeCroy WavePro 7100AXXL uses X-Stream Technology, it is an extremely fast streaming architecture that enables high throughput of data—even when the WavePro oscilloscope is performing complex measurements. It does so by eliminating the trade-offs between long memory lengths and quick processing. Specifications. DC to 1 GHz Bandwidth, 4 input channels. Input impedance: 1 M ohm (approx. 15 pF), or 50 ohm ±1%. Trigger Sensitivity: 2 div p-p (DC to 1 GHz). Vertical Voltage axis sensitivity: 2 mV/div to 1 V/div. Horizontal Time axis accuracy: ±(0.01% + 500 ps). Rise Time: 400 ps. Sampling rate; Max: 20 GS/s, Per channel: 10 GS/s. Record length; Max: 100 M words, Per channel: 50 M words. Display, LCD: 10.4-inch TFT, color (800 x 600 pixels).



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the LECROY WAVEPRO 7100AXXL. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your LECROY WAVEPRO 7100AXXL CALIBRATION and/or LECROY WAVEPRO 7100AXXL 4 Ch 1 GHz WavePro Digital Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: